Boat Compatibility

Mastervolt MasterBus N2K interface: NMEA 2000 PGN list

Gateway / converter from Mastervolt. Mastervolt's published list says it sends 14 and receives 13 standard data messages (PGNs), plus 3 network-management messages.

PGNs (Parameter Group Numbers) are the numbered NMEA 2000 messages devices use to share data. Two devices share a kind of data when one maker's list says it sends a PGN and the other maker's list says it receives the same PGN.

Check before buying. Medium confidence: dealer mirror of manufacturer PDF.

Check it with the rest of my boat →

Check with the manufacturer before buying. These results only compare the lists of data messages (PGNs) that makers publish. Firmware, settings and wiring can change what actually works.

PGNs by data type

From: MasterBus – NMEA 2000 Interface User's Manual, July 2011. Last checked 2026-11-19.

Position & time

PGNMessageSendsReceives
129025Position, Rapid Update–Yes
129026COG & SOG, Rapid Update–Yes
129029GNSS Position Data–Yes

Wind

PGNMessageSendsReceives
130306Wind Data–Yes

Temperature & weather

PGNMessageSendsReceives
130322Current Station Data–Yes

Route & waypoint navigation

PGNMessageSendsReceives
129284Navigation Data–Yes
130577Direction Data–Yes

Autopilot & steering

PGNMessageSendsReceives
127245Rudder–Yes

AIS & targets

PGNMessageSendsReceives
129794AIS Class A Static and Voyage Related Data–Yes

Engine & propulsion

PGNMessageSendsReceives
127488Engine Parameters, Rapid Update–Yes
127489Engine Parameters, Dynamic–Yes
127493Transmission Parameters, Dynamic–Yes

Batteries & DC power

PGNMessageSendsReceives
127506DC Detailed StatusYes–
127507Charger StatusYes–
127508Battery StatusYesYes
127509Inverter StatusYes–
127510Charger Configuration StatusYes–
127511Inverter Configuration StatusYes–
127513Battery Configuration StatusYes–

AC power & generator

PGNMessageSendsReceives
65018Generator Total AC EnergyYes–
65025Generator Phase A AC Reactive PowerYes–
65026Generator Phase A AC PowerYes–
65027Generator Phase A Basic AC QuantitiesYes–

Tank levels

PGNMessageSendsReceives
127505Fluid LevelYes–

Switching, lighting & trim

PGNMessageSendsReceives
127501Binary Switch Bank StatusYes–
127502Switch Bank ControlYes–
Network-management messages (3)

Used by every NMEA 2000 device to join the network. Not counted when we compare devices.

PGNMessageSendsReceives
59904ISO RequestYes–
60928ISO Address ClaimYes–
126996Product InformationYes–

Other brands that share data with it

Confirmed by both makers' full published lists (same rule as the checker). Maker-specific messages don't count between brands.

And 31 more in the checker.

Source